The SPO2 Fingertip Pulse Oximeter Blood Oxygen Monitor measures oxygen saturation in the blood using an optical sensor, typically clipped to a fingertip. This value is expressed as a percentage (%), which represents the percentage of oxygen in the blood to the total blood volume. Under normal circumstances, blood oxygen saturation should be above 95%, and less than 90% may indicate insufficient oxygen supply and require medical intervention. The readings of the SPO2 Fingertip Pulse Oximeter Blood Oxygen Monitor are very accurate. Clinical trials have proven that its accuracy and reliability are superior to similar instruments, making it a fast and reliable instrument. Suitable for oxygen and pulse measurement with minimal error. Find a huge selection of SPO2 Fingertip Pulse Oximeter Blood Oxygen Monitor from China at KINGSTAR INC.
1.Do not use the Fingertip Pulse Oximeter together with MRI or CT equipment.
2.Explosion hazard: Do not use the Fingertip Pulse Oximeter in an explosive atmosphere.
3.The Fingertip Pulse Oximeter is intended only as an adjunct in patient assessment. Doctors should make diagnosis in conjunction with clinical manifestation and symptoms.
4.Check the Fingertip Pulse Oximeter sensor application site frequently to make sure that the circulation and skin integrality of patient are under good condition.
5.Do not stretch the adhesive tape while applying the Fingertip Pulse Oximeter sensor. This may cause inaccurate reading or skin blisters.
6.Please read the manual carefully before your operation.
7.The Fingertip Pulse Oximeter has no SpO2 prompt, it is not for continuous monitoring.
8.Prolonged use or the patient’s condition may require changing the sensor site periodically. Change sensor site and check skin integrality, circulatory status, and correct alignment at least every 2 hours.
9.Inaccurate measurements may be caused by autoclaving, ethylene oxide sterilizing, or immersing the sensors in liquid.
10.Significant levels of dysfunctional hemoglobins (such as carboxylhemoglobin or methemoglobin) may cause inaccurate reading.
11.Intravascular dyes such as indocyanine green or methylene blue may cause inaccurate reading.
12.SpO2 measurements may be adversely affected in the presence of high ambient light. Please shield the sensor area (with a surgical towel or direct sunlight, for example) if it is necessary.
13.Unexpected action may cause inaccurate reading.
14.Medical signal with high frequency or interference caused by defibrillator may lead to inaccurate reading.
15.Venous pulsations may cause inaccurate reading.
SPO2(Blood oxygen saturation levels) is an important physiological parameter of the respiratory cycle.
SPO2 Fingertip Pulse Oximeter Blood Oxygen Monitor is a quick and precise way to check pulse rates and blood oxygen saturation levels.
Self-adjusting finger clamp plus simple one-button design allows for easy operation. Small portable size makes it easy to handle and carry. Helpful for athletes and pilots to obtain quick and precise oxygen saturation readings.
Basic Information |
|
Power Supply |
two AAA 1.5V alkaline batteries |
Power Consumption |
below 30mAh |
Automatically Power-off |
The product automatically shuts off when no signal can be detected within 8 seconds |
Dimension |
Approx. 58mm×35mm×30mm |
SPO2 |
|
Measurement range |
70%~99% |
Accuracy |
±3% on the stage of 70%~99% |
Resolution |
±1% |
PR |
|
Measurement range |
30BPM~240 BPM |
Accuracy |
±2BPM |
Operation Environment |
|
Operation Temperature |
5℃~40℃ |
Storage Temperature |
-10℃~40℃ |
Operation Humidity |
15%~80% |
Storage Humidity |
10%~80% |
Air Pressure |
70kPa~106kPa |
SPO2 Fingertip Pulse Oximeter Blood Oxygen Monitor is compact and easily portable to take with you throughout your day
SPO2 Fingertip Pulse Oximeter Blood Oxygen Monitor is suitable for all ages.
Our oxygen saturation Fingertip Pulse Oximeter can be used as a pediatric pulse oximeter not only for kids but also as a blood oxygen monitor for adults
Our SPO2 Fingertip Pulse Oximeter Blood Oxygen Monitor is easy to use and has efficient one-button operation.
It will spot check and display SpO2, PR, pulse bar graph in real time, which is very suitable for checking your pulse signal strength
The following is the certificates of SPO2 Fingertip Pulse Oximeter Blood Oxygen Monitor.